How to read the car air conditioner plus fluoride meter

2025-10-01 22:48:30 Real Estate

How to read the car air conditioner plus fluoride meter

As the temperature rises in summer, the frequency of automobile air conditioners also increases. When the air conditioner is not refrigerated, it may be that the refrigerant (fluorine) is insufficient. At this time, it is necessary to use a fluorine meter to detect and replenish. This article will introduce in detail how to correctly read the fluoride table of the car air conditioner and attach relevant data to help car owners and maintenance personnel operate better.

1. Basic structure of automotive air conditioner plus fluoride meter

How to read the car air conditioner plus fluoride meter

Automobile air conditioner fluoride meter is usually composed of a high-pressure gauge and a low-pressure gauge, which is used to measure the pressure on the high-pressure and low-pressure side of the air conditioner system, respectively. Here are the main components of the fluoride table:

Part NameFunction description
High voltage gaugesDisplays the pressure on the high-pressure side of the air conditioning system, usually with a red scale
Low voltage meterDisplays the pressure on the low-pressure side of the air conditioning system, usually in blue scale
Connecting hoseUsed to connect fluoride meter and air conditioning system
valveControl the flow direction of refrigerant

2. How to read the data of the fluoride table

When reading a fluoride meter, you need to pay attention to the values ​​of high-pressure meter and low-pressure meter and compare it with the standard values. The following are the air conditioning pressure reference values ​​for common models:

Car modelLow-pressure side pressure (PSI)High Pressure Side Pressure (PSI)
Family car25-45150-250
SUV30-50160-270
Business car35-55170-290

Notes:

1. When reading data, make sure the engine is in operation, the air conditioner is turned on and adjusted to maximum cooling mode.

2. The ambient temperature will affect the pressure value. It is recommended to conduct testing in an environment of 20-30 degrees Celsius.

3. If the pressure value is abnormal, it may indicate that there is leakage or blockage in the air conditioning system, and further inspection is required.

3. Judgment of abnormalities in fluoride table

Through the reading of the fluoride meter, the cause of the failure of the air conditioning system can be preliminarily judged. The following are common abnormalities and possible causes:

AnomalyPossible Causes
Low pressure side pressure is too lowInsufficient refrigerant, failure of expansion valve
Excessive pressure on the high pressure sidePoor heat dissipation of the condenser and excessive refrigerant
The pressure on both high and low pressure sides is too lowThere is a leak in the system
The pressure on both high and low pressure sides is too highExcessive air or refrigerant in the system

4. Operation steps

1.Connect the fluoride table:Connect the fluoride meter hoses to the high-voltage and low-voltage interfaces of the air-conditioning system respectively.

2.Start the engine:Turn on the air conditioner and adjust to the maximum cooling mode to keep the engine speed at 1500-2000 rpm.

3.Read data:Observe the readings of high and low pressure gauges and compare them with the standard values.

4.Refrigerant supplement:If the pressure is too low, refrigerant can be replenished through the low pressure side until the pressure returns to normal.

5.Check for leaks:If the pressure is abnormal, check whether there is any leakage in the system and repair it if necessary.

5. Safety precautions

1. Wear protective gloves and glasses during operation to avoid refrigerant from touching the skin or eyes.

2. Refrigerant is a flammable and explosive substance and needs to be kept away from the fire source.

3. If you are not familiar with the operation, it is recommended to seek help from professional maintenance personnel.

Summarize

Correct reading of the fluoride meter of the car air conditioner is a key step to ensure the normal operation of the air conditioner system. Through the introduction of this article, I hope you can master the use of fluoride tables and pay attention to safety in actual operation. If you encounter complex problems, it is recommended to contact professional maintenance personnel in time to avoid greater losses due to improper operation.

Next article
  • How to read the car air conditioner plus fluoride meterAs the temperature rises in summer, the frequency of automobile air conditioners also increases. When the air conditioner is not refrigerated, it may be that the refrigerant (fluorine) is insufficient. At this time, it is necessary to use a fluorine meter to detect and replenish. This article will introduce in detail how to correctly read the fluoride table of th
    2025-10-01 Real Estate
  • How to turn on the camera in Win7On Windows 7 systems, turning on the camera is a common requirement, whether it is for video calls, taking photos or recording videos. This article will introduce in detail several ways to turn on the camera in Win7 system, and attach a table of relevant operation steps to help users quickly solve problems.1. Check the camera through the device managerFirst, make sure the camera is co